Museums light works on paper, textiles and photographs at 50 lux, oil and acrylic paintings at 150 lux, and stone and metal at 300 lux, with ultraviolet kept below 75 microwatts per lumen. Light-sensitive work also gets an annual budget of about 50,000 lux hours, then years of rest.
By Travis Moher · Published November 17, 2026
Light damage is cumulative and it does not reverse. A watercolor does not recover when you turn the lamp off; it just stops getting worse for a while. That is why conservators manage light two ways: a ceiling on brightness (lux) and a ceiling on total dose over a year (lux hours). Below are the published numbers we work from at the gallery, what each one means, and how to translate them to a wall at home.
The 50 lux rule, explained
The Canadian Conservation Institute explains where 50 lux came from: color science established that 50 lux is enough for a young viewer's eye to work in full color vision, and conservation adopted it as the benchmark. From that base came three traditional levels that most museum lending agreements still follow: 50 lux for textiles, works on paper, watercolors and photographs; 150 lux for oil and acrylic paint surfaces, panels and furniture; and 300 lux for stone and metal.
One lux is one lumen per square meter. US lighting specs often use footcandles instead; one footcandle is about 10.8 lux, and CCAHA rounds it to 11. So 50 lux is about 5 footcandles.
Lux levels and annual budgets by medium
| Medium | Max lux | Footcandles | Annual budget | Rest after display |
|---|---|---|---|---|
| Works on paper, watercolors, prints, drawings | 50 lux | about 5 fc | 50,000 lux hours | 3 years minimum |
| Textiles, photographs, feathers | 50 lux | about 5 fc | 50,000 lux hours | 3 years minimum |
| Oil and acrylic paintings, panels, polychrome | 150 lux | about 14 fc | 100,000 lux hours | 2 years minimum |
| Wood, leather, furniture | 150 lux | about 14 fc | 100,000 lux hours | 2 years minimum |
| Stone, metal, ceramics, glass | 300 lux | about 28 fc | 300,000 lux hours | 1 year minimum |
Lux levels from the Canadian Conservation Institute. Annual budgets and rest periods from CCAHA's exhibition guidance, which assumes UV and infrared are filtered and RH is held at 40 to 60%. UV for every category: ideally 0 to 10 µW/lm, maximum 75 µW/lm.
How lux hours work
Dose is brightness times time. CCAHA's formula is simply lux multiplied by hours per day multiplied by days. Its 50,000 lux hour budget for a watercolor could be 50 lux for 10 hours a day over 100 days, or any other combination that lands at or under the total. Then the piece rests in the dark for at least three years.
Here is why that matters at home. A print lit at 50 lux for 8 hours a day, every day of the year, takes about 146,000 lux hours, nearly three times the museum budget, even though the brightness itself is “museum correct.” A spot reading can look perfect while the annual total is far over.
The CCI puts the stakes in years. For the most light-sensitive colors (ISO Blue Wool 1 to 3), it estimates a just noticeable fade after 1.5 to 20 years at 50 lux, 0.5 to 7 years at 150 lux, and only 5 days to 2 months at 5,000 lux, the level near a window or under a study lamp. Those estimates assume about 3,000 display hours a year.
UV limits in microwatts per lumen
Ultraviolet adds damage without adding anything you can see. The traditional rule, which CCAHA calls the standard, is to keep UV below 75 µW/lm, the output of an ordinary incandescent bulb. CCAHA lists 0 to 10 µW/lm as ideal. For scale, the CCI gives these reference levels:
| Light source | UV (µW/lm) |
|---|---|
| Open daylight | about 600 to 1,000 |
| Daylight through window glass | about 400 to 500 |
| Daylight through a good UV filter | 75 or less |
| Ordinary incandescent lamp | 75 |
| Conservation ideal (CCAHA) | 0 to 10 |
Window glass alone does not make daylight safe: it still passes several times the 75 µW/lm limit. UV-filtering glazing on the frame and UV film on the window do the real work. Our guide to protecting art from fading covers glazing choices in detail.
How to measure with a phone lux meter
A phone app is a screening tool, not a meter. The German lighting lab DIAL tested seven apps on seven phones against a calibrated class A meter. Deviations ran as high as 113%. iPhones read a median of about 60% low; Android and Windows phones read about 60% high. Four identical iPhones gave noticeably different readings.
Used with that in mind, a phone still helps:
- •Measure at the art. Hold the phone flat against the center of the piece, sensor facing the room and the light source, at the time of day the wall is brightest.
- •Compare, do not certify. Readings are most useful relative to each other: which wall is three times brighter, which lamp adds the most.
- •Assume an iPhone is reading low. If an iPhone already shows more than 150 lux on a watercolor, the real figure is likely higher still. Move the piece or dim the light.
- •Buy a real meter for real work. For an original on paper or a valuable photograph, a calibrated light meter is the only reading worth acting on.
What the numbers mean at home
Most homes are much brighter than a gallery where it counts. The CCI uses 500 lux as a typical office level, 5,000 lux beside a window or under a study lamp, and 30,000 lux for average daylight. A watercolor on a sunny wall can take its whole annual budget in an afternoon. Practical steps, in order of payoff:
- •Keep paper, photos and textiles off sunlit walls. Direct sun is the single biggest dose in any house.
- •Frame works on paper under UV-filtering glazing. It handles the UV, though not the visible light.
- •Light the art only when you are in the room. A timer or dimmer cuts lux hours more than any bulb choice.
- •Rotate sensitive pieces. Museums rest paper for three years after a display cycle. At home, swapping prints seasonally follows the same logic.
For fixture and color temperature choices, see how to light artwork at home.
Exceptions and distinctions
- •Medium is about the colorant, not the support. A gouache on board is a 50 lux object, even though the board is sturdy. Oil on paper still behaves like a work on paper.
- •Prints vary by ink. A giclee with pigment inks is far more lightfast than a dye-based print, but no print is a 300 lux object. Ratings like Blue Wool are explained in our lightfastness ratings guide.
- •Brightness level and dose are different limits. Meeting 50 lux does not mean a piece can hang forever. The annual budget is the limit most homes break.
- •Galleries run a little brighter. NEDCC's guidance for exhibit spaces is 50 to 150 lux, with very fragile material kept off permanent display.
- •Storage beats display for the most fragile work. A piece in a dark archival box uses none of its budget.
- •Color rendering matters too. The CCI recommends a color rendering index of at least 85 for exhibit lighting, and many museums specify above 90.
Free to use
Put this lighting chart on your site
Writing about art care, framing or display lighting? Embed our museum lux chart for your readers. Copy the snippet below. It renders a clean, responsive table anywhere. The only ask: keep the small credit link to Austin Gallery.
Click inside the box, select all (⌘A or Ctrl+A), and copy. Includes one credit link back to this page.
Frequently asked questions
How many lux is safe for artwork?
It depends on the medium. The traditional conservation levels are 50 lux for works on paper, watercolors, textiles and photographs, 150 lux for oil and acrylic paintings, and 300 lux for stone and metal, according to the Canadian Conservation Institute.
What is the 50 lux rule?
The 50 lux rule is the conservation benchmark that light-sensitive works such as watercolors, prints, drawings, photographs and textiles should be displayed at about 50 lux (roughly 5 footcandles). The Canadian Conservation Institute describes 50 lux as enough for the eye to see full color well.
How many lux hours per year can a watercolor or print take?
CCAHA recommends a total of 50,000 lux hours per year for very light-sensitive objects such as textiles, watercolors, photographs and papers, followed by at least 3 years of rest between display cycles. Paintings, wood and leather get 100,000 lux hours per year.
What is the UV limit for museum lighting?
The standard limit is 75 microwatts per lumen (µW/lm). CCAHA treats 75 µW/lm as the maximum and 0 to 10 µW/lm as ideal. Daylight through ordinary window glass runs about 400 to 500 µW/lm, per the Canadian Conservation Institute.
How many lux is a typical living room?
It varies widely, but the Canadian Conservation Institute uses 500 lux as a typical office level, 5,000 lux for a spot by a window or under a study lamp, and 30,000 lux for average daylight. All of these are far above the 50 lux used for works on paper.
Can I measure lux with my phone?
Only roughly. A test by the German lighting lab DIAL found phone lux apps off by as much as 113%, with iPhones reading a median of about 60% low and Android phones about 60% high. Use a phone to compare spots, and a calibrated meter for valuable work.
How long does it take for a watercolor to fade at 50 lux?
For highly sensitive colors (ISO Blue Wool 1 to 3), the Canadian Conservation Institute estimates a just noticeable fade after 1.5 to 20 years at 50 lux, assuming about 3,000 display hours a year. At 5,000 lux, the same fade can take only 5 days to 2 months.
How many footcandles is 50 lux?
About 5 footcandles. One footcandle equals roughly 10.8 lux (CCAHA rounds it to 11), so 150 lux is about 14 footcandles and 300 lux is about 28 footcandles.
Sources
- Canadian Conservation Institute, Agent of Deterioration: Light, Ultraviolet and Infrared (50, 150 and 300 lux levels; 75 µW/lm; UV by light source; years to noticeable fade; CRI)
- CCAHA, Light Exposure for Artifacts on Exhibition (annual lux hour budgets, rest periods, 0 to 10 µW/lm ideal)
- NEDCC Preservation Leaflet 2.1, Temperature, Relative Humidity, Light, and Air Quality (50 to 150 lux for exhibit spaces)
- DIAL, Luxmeter App vs. Measuring Device (phone app accuracy test)
Austin Gallery's care notes are general guidance, not conservation treatment advice. For a valuable or irreplaceable piece, consult a professional conservator about your specific environment.
Cite this guide
Writers, framers, designers and students are welcome to quote this page. If you use one number, use this one:
Museums light works on paper, textiles and photographs at 50 lux, oil and acrylic paintings at 150 lux, and stone and metal at 300 lux, with UV kept below 75 microwatts per lumen.
Suggested citation:
Austin Gallery, "Museum Lighting Lux Levels: The 50 Lux Rule by Medium," updated November 2026. https://www.austingallery.org/blog/museum-lighting-lux-levels
More free charts: the Austin Gallery reference library.